Cable screens to XLR pin 1
The screen of each separate microphone cable and/or
the screen of each single pair in a multi-pair cable,
should be connected to pin 1 of each XLR-3
connector. Do not connect these screens to the metal
housing of ASL unitst or XLR-3 wall boxes. See
section ‘Earthing Concept’.
Connect metal cable trunks, wall boxes and
overall multi-pair cable screens to clean earth
Metal cable trunks, metal wall boxes and overall multi-
pair cable screens should be interconnected and, at
the 'central earth point' in the intercom network only,
be connected to a clean earth or a safety earth. (see
section ‘Earthing Concept’).
Keep metal connection boxes and cable trunks or
pipes isolated from other metal parts
Metal trunks or pipes for intercom cables and metal
connection boxes should be mounted in such a way
that they are isolated from any other metal housing or
construction part.
Keep cables parallel as much as possible
When two (multi channel) units in a network are
connected by more than one cable, make sure that
these cables are parallel to each other over the whole
distance between those units. When using multi-pair
cable, parallelism is ensured in the best possible way.
Avoid closed loops
Always avoid that intercom cables are making a
closed loop. So-called 'ring intercom' should not
physically be cabled as a ring
Keep cables away from electromagnetic sources
Keep intercom cables away from high energy cables,
e.g. 115/230/400V mains power or dimmer controlled
feeds for spotlights. Intercom cables should cross high
energy cables at an angle of 90º only. Intercom cables
should never be in the same trunks as energy cables.
Place power supply in a central position
In case of a system powered by a separate power
supply: In order to diminish power losses, place the
power supply as close as possible to where most
power consumption occurs, in other words most user
stations are placed.
ASL powered units to a 'clean' mains outlet
Master stations or power supplies should be connected
to a mains outlet with a clean earth. Other audio
equipment may be connected to this mains outlet, but
avoid using an outlet which also powers dimmer
controlled lighting systems.